<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>CAME SMA &#8211; CAME Gate Automation &amp; Intercom Systems UK | Came Products</title>
	<atom:link href="https://www.cameproducts.co.uk/product-tag/came-sma/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.cameproducts.co.uk</link>
	<description>Shop CAME gate automation systems, barriers, intercom systems &#38; spare parts in the UK. Expert support, fast delivery</description>
	<lastBuildDate>Mon, 27 Jul 2026 14:43:42 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://i0.wp.com/www.cameproducts.co.uk/wp-content/uploads/2025/01/cropped-camesitelogo-for-web-1.png?fit=32%2C32&#038;ssl=1</url>
	<title>CAME SMA &#8211; CAME Gate Automation &amp; Intercom Systems UK | Came Products</title>
	<link>https://www.cameproducts.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">137032416</site>	<item>
		<title>CAME SMA &#038; SMA2 Induction Loop Detectors &#124; Gates &#038; Barriers</title>
		<link>https://www.cameproducts.co.uk/shop/came-accessories/digitalandkeyswitchselectors/came-loop-controller-sensor/</link>
					<comments>https://www.cameproducts.co.uk/shop/came-accessories/digitalandkeyswitchselectors/came-loop-controller-sensor/#respond</comments>
		
		<dc:creator><![CDATA[cameproducts]]></dc:creator>
		<pubDate>Wed, 13 Dec 2017 09:24:48 +0000</pubDate>
				<guid isPermaLink="false">http://www.cameproducts.co.uk/?post_type=product&#038;p=450</guid>

					<description><![CDATA[<span class="citation-1394">The CAME loop controller series, most notably the </span><b data-path-to-node="0" data-index-in-node="50"><span class="citation-1394">SMA</span></b><span class="citation-1394"> (Single Channel) and </span><b data-path-to-node="0" data-index-in-node="75"><span class="citation-1394">SMA2</span></b><span class="citation-1394 citation-end-1394"> (Dual Channel), are professional-grade inductive vehicle detectors designed for automated gates, barriers, and bollards.</span> <span class="citation-1393 citation-end-1393">They work by monitoring the resonance of a buried wire loop to detect the presence of metal objects, such as vehicles.</span>

<a href="http://www.cameproducts.co.uk/wp-content/uploads/2017/10/cropped-cameproductslogo.gif"><img class="alignnone size-full wp-image-92" src="http://www.cameproducts.co.uk/wp-content/uploads/2017/10/cropped-cameproductslogo.gif" alt="" width="119" height="110" /></a>]]></description>
										<content:encoded><![CDATA[<p id="p-rc_01479627cf8c2a62-732" data-path-to-node="0"><span class="citation-1394">The CAME loop controller series, most notably the </span><b data-path-to-node="0" data-index-in-node="50"><span class="citation-1394">SMA</span></b><span class="citation-1394"> (Single Channel) and </span><b data-path-to-node="0" data-index-in-node="75"><span class="citation-1394">SMA2</span></b><span class="citation-1394 citation-end-1394"> (Dual Channel), are professional-grade inductive vehicle detectors designed for automated gates, barriers, and bollards.</span> <span class="citation-1393 citation-end-1393">They work by monitoring the resonance of a buried wire loop to detect the presence of metal objects, such as vehicles.</span></p>
<h3 data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">Core CAME Loop Detector Models</b></h3>
<table data-path-to-node="2">
<thead>
<tr>
<td><strong>Model</strong></td>
<td><strong>Type</strong></td>
<td><strong>Best For</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td><span data-path-to-node="2,1,0,0"><b data-path-to-node="2,1,0,0" data-index-in-node="0">CAME SMA</b></span></td>
<td><span data-path-to-node="2,1,1,0">Single Channel</span></td>
<td><span data-path-to-node="2,1,2,0">Standard exit or safety loops at gate/barrier entrances.</span></td>
</tr>
<tr>
<td><span data-path-to-node="2,2,0,0"><b data-path-to-node="2,2,0,0" data-index-in-node="0">CAME SMA2</b></span></td>
<td><span data-path-to-node="2,2,1,0">Dual Channel</span></td>
<td><span data-path-to-node="2,2,2,0">Complex installations requiring two separate detection zones (e.g., safety + activation).</span></td>
</tr>
</tbody>
</table>
<h3 data-path-to-node="4"><b data-path-to-node="4" data-index-in-node="0">Key Features</b></h3>
<ul data-path-to-node="5">
<li>
<p id="p-rc_01479627cf8c2a62-733" data-path-to-node="5,0,0"><b data-path-to-node="5,0,0" data-index-in-node="0">Precision Tuning:</b><span class="citation-1392 citation-end-1392"> Both models feature multi-level sensitivity adjustments (typically 9 levels), allowing you to fine-tune detection so the system ignores small metal objects while reliably catching cars, trucks, or trailers.</span></p>
</li>
<li>
<p id="p-rc_01479627cf8c2a62-734" data-path-to-node="5,1,0"><b data-path-to-node="5,1,0" data-index-in-node="0"><span class="citation-1391">Frequency Selection:</span></b><span class="citation-1391 citation-end-1391"> Multiple selectable operating frequencies allow you to install adjacent loops without signal interference (cross-talk).</span></p>
</li>
<li>
<p data-path-to-node="5,2,0"><b data-path-to-node="5,2,0" data-index-in-node="0">Advanced Logic:</b> Includes features like:</p>
<ul data-path-to-node="5,2,1">
<li>
<p data-path-to-node="5,2,1,0,0"><b data-path-to-node="5,2,1,0,0" data-index-in-node="0">Automatic Sensitivity Boost (ASB):</b> Helps detect high-bed vehicles or those with drawbars.</p>
</li>
<li>
<p id="p-rc_01479627cf8c2a62-735" data-path-to-node="5,2,1,1,0"><b data-path-to-node="5,2,1,1,0" data-index-in-node="0">Time Functions:</b><span class="citation-1390 citation-end-1390"> Supports switch-on/off delays and &#8220;presence&#8221; modes where the signal stays active as long as the vehicle is over the loop.</span></p>
</li>
</ul>
</li>
<li>
<p id="p-rc_01479627cf8c2a62-736" data-path-to-node="5,3,0"><b data-path-to-node="5,3,0" data-index-in-node="0"><span class="citation-1389">Ease of Installation:</span></b><span class="citation-1389 citation-end-1389"> DIN rail mounting makes them standard for control cabinet integration.</span> They feature clear LCD displays and configuration buttons for quick setup.</p>
</li>
<li>
<p id="p-rc_01479627cf8c2a62-737" data-path-to-node="5,4,0"><b data-path-to-node="5,4,0" data-index-in-node="0">Fail-Safe/Fail-Secure:</b><span class="citation-1388 citation-end-1388"> Options available to ensure your gate remains secure or opens automatically in the event of a power failure or loop fault.</span></p>
</li>
</ul>
<h3 data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">How They Work</b></h3>
<ol start="1" data-path-to-node="8">
<li>
<p id="p-rc_01479627cf8c2a62-738" data-path-to-node="8,0,0"><b data-path-to-node="8,0,0" data-index-in-node="0"><span class="citation-1387">Inductive Loop:</span></b><span class="citation-1387 citation-end-1387"> A copper wire is installed beneath the road surface (usually in a rectangular &#8220;saw-cut&#8221; or buried in a pipe/duct).</span></p>
</li>
<li>
<p data-path-to-node="8,1,0"><b data-path-to-node="8,1,0" data-index-in-node="0">Magnetic Field:</b> The CAME controller sends electricity through the loop, creating a localized magnetic field.</p>
</li>
<li>
<p id="p-rc_01479627cf8c2a62-739" data-path-to-node="8,2,0"><b data-path-to-node="8,2,0" data-index-in-node="0"><span class="citation-1386">Detection:</span></b><span class="citation-1386 citation-end-1386"> When a large metal object (your vehicle) enters this field, it changes the inductance (the &#8220;resonant frequency&#8221;) of the loop.</span></p>
</li>
<li>
<p data-path-to-node="8,3,0"><b data-path-to-node="8,3,0" data-index-in-node="0">Signal:</b> The controller senses this change and triggers a relay, sending a signal to your gate’s control board to either open the gate or hold it open for safety.</p>
</li>
</ol>
]]></content:encoded>
					
					<wfw:commentRss>https://www.cameproducts.co.uk/shop/came-accessories/digitalandkeyswitchselectors/came-loop-controller-sensor/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">450</post-id>	</item>
	</channel>
</rss>
