<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>BPT Intercom Relay &#8211; CAME Gate Automation &amp; Intercom Systems UK | Came Products</title>
	<atom:link href="https://www.cameproducts.co.uk/product-tag/bpt-intercom-relay/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.cameproducts.co.uk</link>
	<description>Shop CAME gate automation systems, barriers, intercom systems &#38; spare parts in the UK. Expert support, fast delivery</description>
	<lastBuildDate>Sat, 13 Jun 2026 09:43:57 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://i0.wp.com/www.cameproducts.co.uk/wp-content/uploads/2025/01/cropped-camesitelogo-for-web-1.png?fit=32%2C32&#038;ssl=1</url>
	<title>BPT Intercom Relay &#8211; CAME Gate Automation &amp; Intercom Systems UK | Came Products</title>
	<link>https://www.cameproducts.co.uk</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">137032416</site>	<item>
		<title>CAME BPT R/1 Auxiliary Relay Unit &#124; Intercom and Gate Control</title>
		<link>https://www.cameproducts.co.uk/shop/intercomsystems/intercom-system-components/came-bpt-relay-unit-r-1/</link>
					<comments>https://www.cameproducts.co.uk/shop/intercomsystems/intercom-system-components/came-bpt-relay-unit-r-1/#respond</comments>
		
		<dc:creator><![CDATA[cameproducts]]></dc:creator>
		<pubDate>Mon, 30 Mar 2026 12:39:07 +0000</pubDate>
				<guid isPermaLink="false">https://www.cameproducts.co.uk/?post_type=product&#038;p=22769</guid>

					<description><![CDATA[The <b data-path-to-node="1" data-index-in-node="4">CAME BPT R/1 Relay Unit</b> is a versatile, high-reliability auxiliary interface designed for intercom and access control systems. It enables seamless integration between low-voltage entry panels/monitors and higher-load peripheral devices, such as electric gate locks, perimeter lighting, or secondary automation equipment. Featuring dual clean (isolated) contacts, the R/1 acts as a switching bridge, allowing an intercom’s auxiliary command signal to safely trigger external hardware. Housed in a compact, DIN-rail mountable module with wide voltage compatibility (8–28V DC / 8–24V AC) and an integrated status LED, it is the essential component for expanding the command capabilities of BPT and CAME entry systems.

<a href="https://www.cameproducts.co.uk/wp-content/uploads/2017/10/cameproductslogo.gif"><img class="alignnone size-thumbnail wp-image-84" src="https://www.cameproducts.co.uk/wp-content/uploads/2017/10/cameproductslogo-150x150.gif" alt="" width="150" height="150" /></a>]]></description>
										<content:encoded><![CDATA[<p id="p-rc_cd3a072541e356e7-366" data-path-to-node="0">The <b data-path-to-node="0" data-index-in-node="4">CAME BPT R/1</b> is a versatile auxiliary relay unit primarily used in intercom and door entry systems. <span class="citation-714 citation-end-714">It acts as an interface to bridge low-voltage signals from an indoor monitor or entry panel to higher-load devices, such as electric locks, gates, or other auxiliary equipment.</span></p>
<h3 data-path-to-node="1"><b data-path-to-node="1" data-index-in-node="0">Core Functionality</b></h3>
<p id="p-rc_cd3a072541e356e7-367" data-path-to-node="2"><span class="citation-713 citation-end-713">The R/1 is designed to &#8220;multiply&#8221; or &#8220;strengthen&#8221; contacts.</span> For example, if an indoor intercom monitor does not have the power capacity to trigger a heavy-duty electric gate lock directly, the R/1 relay is triggered by the monitor’s low-power signal, which in turn switches the higher-power circuit required to operate the lock.</p>
<h3 data-path-to-node="4"><b data-path-to-node="4" data-index-in-node="0">Key Features</b></h3>
<ul data-path-to-node="5">
<li>
<p id="p-rc_cd3a072541e356e7-368" data-path-to-node="5,0,0"><b data-path-to-node="5,0,0" data-index-in-node="0"><span class="citation-712">Two Clean Contacts:</span></b><span class="citation-712 citation-end-712"> Provides two isolated, independent output channels (Double Pole, Double Throw).</span></p>
</li>
<li>
<p id="p-rc_cd3a072541e356e7-369" data-path-to-node="5,1,0"><b data-path-to-node="5,1,0" data-index-in-node="0"><span class="citation-711">Voltage Flexibility:</span></b><span class="citation-711 citation-end-711"> Features an internal jumper switch that allows the unit to operate across a wide range of voltages, making it compatible with various BPT system configurations.</span></p>
</li>
<li>
<p id="p-rc_cd3a072541e356e7-370" data-path-to-node="5,2,0"><b data-path-to-node="5,2,0" data-index-in-node="0"><span class="citation-710">Visual Status:</span></b><span class="citation-710 citation-end-710"> Equipped with an integrated LED that indicates when the relay is active.</span></p>
</li>
<li>
<p id="p-rc_cd3a072541e356e7-371" data-path-to-node="5,3,0"><b data-path-to-node="5,3,0" data-index-in-node="0"><span class="citation-709">Compact Design:</span></b><span class="citation-709 citation-end-709"> Housed in a durable plastic casing that is typically DIN-rail mountable, making it ideal for installation in electrical cabinets or distribution boards.</span></p>
</li>
</ul>
<h3 data-path-to-node="7"><b data-path-to-node="7" data-index-in-node="0">Technical Specifications</b></h3>
<table data-path-to-node="8">
<thead>
<tr>
<td><strong>Feature</strong></td>
<td><strong>Specification</strong></td>
</tr>
</thead>
<tbody>
<tr>
<td><span data-path-to-node="8,1,0,0"><b data-path-to-node="8,1,0,0" data-index-in-node="0">Supply Voltage</b></span></td>
<td><span data-path-to-node="8,1,1,0">8V – 28V DC or 8V – 24V AC</span></td>
</tr>
<tr>
<td><span data-path-to-node="8,2,0,0"><b data-path-to-node="8,2,0,0" data-index-in-node="0">Relay Outputs</b></span></td>
<td><span data-path-to-node="8,2,1,0">2 Clean Contacts (Changeover: NO, C, NC)</span></td>
</tr>
<tr>
<td><span data-path-to-node="8,3,0,0"><b data-path-to-node="8,3,0,0" data-index-in-node="0">Contact Rating</b></span></td>
<td><span data-path-to-node="8,3,1,0">2A @ 24V DC / 1A @ 120V AC</span></td>
</tr>
<tr>
<td><span data-path-to-node="8,4,0,0"><b data-path-to-node="8,4,0,0" data-index-in-node="0">Dimensions</b></span></td>
<td><span data-path-to-node="8,4,1,0">40 x 60 x 25 mm (H x W x D)</span></td>
</tr>
<tr>
<td><span data-path-to-node="8,5,0,0"><b data-path-to-node="8,5,0,0" data-index-in-node="0">Mounting</b></span></td>
<td><span data-path-to-node="8,5,1,0">Module/PCB / DIN rail</span></td>
</tr>
</tbody>
</table>
<h3 data-path-to-node="10"><b data-path-to-node="10" data-index-in-node="0">Common Applications</b></h3>
<ul data-path-to-node="11">
<li>
<p data-path-to-node="11,0,0"><b data-path-to-node="11,0,0" data-index-in-node="0">Lock Control:</b> Triggering magnetic locks or electric strikes from an intercom handset.</p>
</li>
<li>
<p data-path-to-node="11,1,0"><b data-path-to-node="11,1,0" data-index-in-node="0">Auxiliary Switching:</b> Using an intercom &#8220;Aux&#8221; button to switch on driveway lighting or secondary gate operators.</p>
</li>
<li>
<p data-path-to-node="11,2,0"><b data-path-to-node="11,2,0" data-index-in-node="0">Signal Multiplication:</b> Splitting a single command signal to trigger multiple independent devices simultaneously.</p>
</li>
</ul>
<blockquote data-path-to-node="12">
<p id="p-rc_cd3a072541e356e7-372" data-path-to-node="12,0"><span class="citation-708"><img src="https://s.w.org/images/core/emoji/17.0.2/72x72/26a0.png" alt="⚠" class="wp-smiley" style="height: 1em; max-height: 1em;" /> </span><b data-path-to-node="12,0" data-index-in-node="3"><span class="citation-708">Installation Tip:</span></b><span class="citation-708 citation-end-708"> The R/1 is a &#8220;dry contact&#8221; or &#8220;clean contact&#8221; relay, meaning it does not provide power to the device it is switching; it simply closes a circuit.</span> Ensure that your power supply is correctly sized for the specific lock or device you are intending to drive.</p>
</blockquote>
]]></content:encoded>
					
					<wfw:commentRss>https://www.cameproducts.co.uk/shop/intercomsystems/intercom-system-components/came-bpt-relay-unit-r-1/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">22769</post-id>	</item>
	</channel>
</rss>